Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 2 de 2
Filtrar
Mais filtros










Base de dados
Intervalo de ano de publicação
1.
Cardiol Young ; 33(9): 1643-1648, 2023 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-36124626

RESUMO

Amiodarone may be considered for patients with junctional ectopic tachycardia refractory to treatment with sedation, analgesia, cooling, and electrolyte replacements. There are currently no published pediatric data regarding the hemodynamic effects of the newer amiodarone formulation, PM101, devoid of hypotensive agents used in the original amiodarone formulation. We performed a single-center, retrospective, descriptive study from January 2012 to December 2020 in a pediatric ICU. Thirty-three patients were included (22 male and 11 female) between the ages of 1.1 and 1,460 days who developed post-operative junctional ectopic tachycardia or other tachyarrhythmias requiring PM101. Data analysis was performed on hemodynamic parameters (mean arterial pressures and heart rate) and total PM101 (mg/kg) from hour 0 of amiodarone administration to hour 72. Adverse outcomes were defined as Vasoactive-Inotropic Score >20, patients requiring ECMO or CPR, or patient death. There was no statistically significant decrease in mean arterial pressures within the 6 hours of PM101 administration (p > 0.05), but there was a statistically significant therapeutic decrease in heart rate for resolution of tachyarrhythmia (p < 0.05). Patients received up to 25 mg/kg in an 8-hour time for rate control. Average rate control was achieved within 11.91 hours and average rhythm control within 62 hours. There were four adverse events around the time of PM101 administration, with three determined to not be associated with the medication. PM101 is safe and effective in the pediatric cardiac surgical population. Our study demonstrated that PM101 can be used in a more aggressive dosing regimen than previously reported in pediatric literature with the prior formulation.


Assuntos
Amiodarona , Taquicardia Ectópica de Junção , Humanos , Masculino , Feminino , Criança , Recém-Nascido , Amiodarona/uso terapêutico , Amiodarona/efeitos adversos , Antiarrítmicos/uso terapêutico , Taquicardia Ectópica de Junção/tratamento farmacológico , Estudos Retrospectivos , Taquicardia/tratamento farmacológico , Taquicardia/etiologia , Frequência Cardíaca
2.
Cardiol Young ; 31(12): 1923-1928, 2021 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-33766172

RESUMO

BACKGROUND: Catheter ablation is a safe and effective therapy for the treatment of supraventricular tachycardia in children. Current improvements in technology have allowed progressive reduction in radiation exposure associated with the procedure. To assess the impact of three-dimensional mapping, we compared acute procedural results collected from the Catheter Ablation with Reduction or Elimination of Fluoroscopy registry to published results from the Prospective Assessment after Pediatric Cardiac Ablation study. METHODS: Inclusion and exclusion criteria from the Prospective Assessment after Pediatric Cardiac Ablation study were used as guidelines to select patient data from the Catheter Ablation with Reduction or Elimination of Fluoroscopy registry to compare acute procedural outcomes between cohorts. Outcomes assessed include procedural and fluoroscopy exposure times, success rates of procedure, and complications. RESULTS: In 786 ablation procedures, targeting 498 accessory pathways and 288 atrioventricular nodal reentrant tachycardia substrates, average procedural time (156.5 versus 206.7 minutes, p < 0.01), and fluoroscopy time (1.2 versus 38.3 minutes, p < 0.01) were significantly shorter in the study group. Success rates for the various substrates were similar except for manifest accessory pathways which had a significantly higher success rate in the study group (96.4% versus 93.0%, p < 0.01). Major complication rates were significantly lower in the study group (0.3% versus 1.6%, p < 0.01). CONCLUSIONS: In a large, multicentre study, three-dimensional systems show favourable improvements in clinical outcomes in children undergoing catheter ablation of supraventricular tachycardia compared to the traditional fluoroscopic approach. Further improvements are anticipated as technology advances.


Assuntos
Ablação por Cateter , Taquicardia Supraventricular , Criança , Fluoroscopia , Humanos , Estudos Prospectivos , Taquicardia Supraventricular/cirurgia , Resultado do Tratamento
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...